The simple + reliable flow rate measurement for solids in pneumatic feed and in free fall
The MIC Microwave Measuring System consists of a sensor head with stainless steel pipe and evaluation electronic control unit. To mount the equipment a hole for the integral brackets is first drilled in the conduit. The sensor is installed flush with the wall and therefore is wear-free.
Technical data
| Input | 24 VDC | |
| Current consumption | 0,5 A | |
| Measuring frequency | K - band (24, 125 GHz) | |
| Output | 0 - 20 mA (not normalised) | |
| Reproducibility | +/- 2% | |
| Operating temperature range | -10° C to 65° C / optionally to 170° C | |
| Material | ||
| Sensor | stainless steel/ plastic or ceramic | |
| Housing | aluminium | |
| Protection class | IP 65 | |
| Integral brackets | 1/2“ NPT or as specified by customer | |
| Optional | Ex protection for Zone 20 | |
For further information please see our data sheet
Advantages
- simple installation in existing pipe work
- measurement flush with wall and non-contact
- maintenance-free
- detects only "agitated" particles
- high operating safety
- suitable even for very small quantities